Wella Climazon Millenium Manual Install !exclusive! -

Installing the Wella Climazon Millennium (often referred to as the Climazon 2) requires precision, as these units are heavy-duty infrared hair processors designed for either mobile or wall-mounted professional salon use. Installation Configurations

If you encounter a variation not covered here (e.g., the "Climazon Millennium II" or "Digital" variants), the manual install principles remain identical – only the control panel layout changes. wella climazon millenium manual install

Safety Clearance: Professional reviews emphasize leaving enough clearance for the side arms to swing open fully, as these are adjustable for customized heat distribution. User Experience Tips Installing the Wella Climazon Millennium (often referred to

  1. Remove the rear cover of the wall bracket (2-4 screws).
  2. Identify the terminal block: L (Live/Brown), N (Neutral/Blue), Earth (Green-Yellow).
  3. Run the salon’s supply cable through the cable gland hole in the bracket.
  4. Connect wires to the terminal block:
    • Mount to solid structure – never skip the rawlplugs.
    • Honor the electrical rating – no extension leads.
    • Lock the filter – or destroy the motor.

    Wall-Mounted Version: Typically utilizes the Acrobat 2004 wall arm (models WA04/75 or WA04/95). This arm consists of a boom and a spring arm for flexible positioning. Key Installation Components Remove the rear cover of the wall bracket (2-4 screws)

    Step 2: Mounting the Telescopic Pole

    1. Locate the vertical pole. Notice the small indentation or screw hole at the bottom.
    2. Slide the pole into the base receiver.
    3. Align the hole in the pole with the hole in the base.
    4. Insert the large securing bolt (usually M8) from the hardware kit. Tighten firmly with a wrench. Do not over-torque, but ensure zero wobble.

    The device is typically sold in two main formats, each with distinct mounting requirements: